      Tekmar tN2 House Control -Boiler, DHW & Setpoint, Mixing, Four Zone Valves


      Specifications

      Agency ApprovalsCSA C US, meets class B: ICES & FCC Part 15
      Ambient ConditionsIndoor use only, 32 to 104 degrees F (0 to 40 degrees C), RH less than or equal to 90 percent Non-condensing
      Boiler Stage1 Stage2 Relay24 V (ac) 5 A
      CallsSetpoint and DHW calls, Short, 0 - 32 V (ac)
      Control Load2 VA
      Control TypeMicroprocessor control, this is not a safety (limit) control
      Dimensions5.5" H x 5.5" W x 2.25" D (140 x 140 x 57 mm)
      Enclosure MaterialBlue PC+ABS plastic
      Enclosure NEMA RatingNEMA 1
      Hydronic - HVAC Control TypetN2 House Control
      Modulating OutputBoiler modulation 0 - 10 V (dc) 500 ohms min load impedance, 4 - 20 mA 1 k ohms max load impedance
      Power Supply24 V (ac) plus / minus 10 percent, 60 Hz, 100 VA max, Class 2
      Pump Power115 V (ac) 12 A max
      Pump Relay115 V (ac) 5 A, 1/6 hp
      SensorNTC thermistor, 10 k ohms at 77 degrees F (25 degrees C plus / minus 0.2 degrees C) Beta=3892
      Variable Pump115 V (ac) 2.4 A
      Zone Valve - Floating Action Load89 VA, 24 V (ac), 3.7 A for zones 1 to 4 plus floating action output

      The tekmarNet 2 House Control 402 is designed to operate all the mechanical equipment in a residential hydronic heating system, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler to multiple fan coils, mixed radiant floor heating zones, and a modulating/condensing boiler. This control regulates up to two heating water temperatures through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off, two stage, or modulating boiler, a mixing device, Domestic Hot Water, setpoint loads, 4 on-board zone valves, and can expand up to 24 zones in total for each space heating water temperature.


      Features

      • DHW priority (optional), setpoint operation

      • Exercising, Boiler Protection

      • DHW post purge, DHW control

      • Outdoor temperature reset, indoor temperature feedback

      • Expandable up to 48 zones, single on/off, two stage, or modulating boiler control

      • Variable speed, floating action, or proportional mixing control, automatic boiler differential

      • Warm weather shut down, zone synchronization

      • Only requires 2 Wires Per Zone, Four 24 V (ac) powered zone outputs

      • For use with tekmarNet 2 thermostats only, tN4 expansion terminals

      <p width="420" height="315"></p><div class="media_iframe_video"><div class="css_editable_mode_display">&nbsp;</div><div class="media_iframe_video_size">&nbsp;</div><iframe src="https://www.youtube.com/embed/6p2PMYmgrHw" title="Tekmar Zoning Solutions" alt="Tekmar Zoning Solutions" frameborder="0" allowfullscreen="allowfullscreen"></iframe></div> <span style="font-weight: bold; width: 100%;text-align: center; display: block;">Tekmar Zoning Solutions</span><br><p></p>
      <p width="420" height="315"></p><div class="media_iframe_video"><div class="css_editable_mode_display">&nbsp;</div><div class="media_iframe_video_size">&nbsp;</div><iframe src="https://www.youtube.com/embed/ptlH6mYvT5I" title="Tekmar Reset and Indoor Feedback" alt="Tekmar Reset and Indoor Feedback" frameborder="0" allowfullscreen="allowfullscreen"></iframe></div> <span style="font-weight: bold; width: 100%;text-align: center; display: block;">Tekmar Reset and Indoor Feedback</span><br><p></p>