306V

https://www.pexheat.com/web/image/product.template/15817/image_1920?unique=2a6eb9e

Tekmar Zone Valve Control Six Zones with Priority

214.52 214.52 214.52 USD

214.52

Not Available For Sale

    This combination does not exist.

    306V

    Tekmar Zone Valve Control Six Zones with Priority

      214.52 214.52 214.52 USD

      214.52

      Not Available For Sale

      This combination does not exist.


      Tekmar Zone Valve Control Six Zones with Priority


      Specifications

      ControlMicroprocessor control. This is not a safety (limit) control.
      Packaged weight5.0 lb. (2250 g)
      Dimensions8-3/16" H x 10-11/16" W x 2-3/8" D (208 x 271 x 60 mm)
      EnclosureCover: ABS plastic, Base: galvanized steel, NEMA type 2
      ApprovalsCSA C US
      Ambient conditionsIndoor use only, 32 to 122°F (0 to 50°C), RH ?90% non-condensing
      Power supply115 V (ac) ±10%, 60 Hz, 20 A
      Transformer80VA
      Control load7 VA
      FusesT5A 250 V slow blow, two spare fuses included
      Zone valve outputs24 V (ac), 2 A max per output
      Zone valve end switch24 V (ac)
      System Pump230 V (ac), 5 A, 1/3 hp
      Boiler XX end switch24 V (ac), 5 A
      DHW end switch24 V (ac), 5 A
      Mod boiler output0-10 V (dc) 500 ? min load impedance / 4-20 mA 1 k? max load impedance
      WarrantyLimited 3 Year Warranty

      The Zone Valve Control 306V connects up to six thermostats and operates zone valves to provide heating to a zoned hydronic heating system. The 306V operates a system pump whenever a zone valve opens. Zone 1 can operate either a zone valve or a circulator to provide heat to an indirect domestic hot water tank with optional priority over zones 2 through 6. The 306V includes optional exercising to prevent circulator seizure when not in use, and optional post purge operation of the domestic hot water tank to maximize energy savings. The 306V provides a RoomResponse™ signal to modulating-condensing boilers to optimize comfort while improving boiler efficiency.

      • RoomResponse™ signal, compatible with all low voltage thermostats
      • Compatible with 2, 3 and 4-wire zone valves, unlimited zone expansion
      • Zone priority, priority override
      • Pump exercising, post purge
      • LED for each zone, priority, end switch and RoomResponse™, away signal shared between tekmar thermostats
      • Four ground screws, Top, bottom and back conduit knockouts
      • Fuses protect transformers and pumps
      • Two spare fuses included
      • CSA approved